BLD-2021-2354 Product DataSpecifications subject to change without notice.
Fig. 1 124ANS Unit
NOTE: Images are for illustration purposes only. Actual models may
differ slightly.
Bryant air conditioners with Puron refrigerant provide a collection
of features unmatched by any other family of equipment. The
124ANS has been designed utilizing Bryants Puron refrigerant.
This environmentally sound refrigerant allows you to make a
responsible decision in the protection of the earths ozone layer.
NOTE: Ratings contained in this document are subject to change
at any time. Always refer to the AHRI directory (www.ahridirec-
tory.org) for the most up-to-date ratings information.
TABLE OF CONTENTS
INDUSTRY LEADING FEATURES / BENEFITS ........................1
MODEL NUMBER NOMENCLATURE........................................2
PHYSICAL DATA...........................................................................2
REFRIGERANT PIPING LENGTH LIMITATIONS.....................3
VAPOR LINE SIZING AND COOLING CAPACITY LOSS........5
ACCESSORIES................................................................................6
ELECTRICAL DATA......................................................................8
DIMENSIONS-ENGLISH...............................................................9
DIMENSIONS-SI.............................................................................10
TESTED AHRI COMBINATION RATINGS*...............................11
DETAILED COOLING CAPACITIES ...........................................12
CONDENSER ONLY RATINGS....................................................15
GUIDE SPECIFICATIONS.............................................................17
PRODUCTS .....................................................................................17
INDUSTRY LEADING FEATURES /
BENEFITS
Energy Efficiency
14 SEER/11.7 - 12.2 EER
(Based on tested combinations)
Sound
Levels as low as 66 dBA
Design Features
Small footprint
WeatherArmor cabinet
- All steel cabinet construction
- Mesh coil guard
Reliability, Quality and Toughness
Scroll compressor
Factory-supplied filter drier
High pressure switch
Line lengths up to 250ft (76.2 m)
Low ambient operation (down to -20 F/-28.9 C with low ambient
accessories)
TM
Product Data
124ANS
PREFERREDTM SERIES AIR CONDITIONER
WITH PURON REFRIGERANT
1-1/2 TO 5 NOMINAL TONS
Arnold Hom
11/30/21
2 Specifications subject to change without notice. PDS124ANS-06
MODEL NUMBER NOMENCLATURE
PHYSICAL DATA
* Units are rated with 25 ft. (7.6 m) of lineset length. Review the VAPOR LINE SIZING AND COOLING CAPACITY LOSS section when using other lineset sizes and lengths of
lineset.
Note: Review the units Installation Instructions for proper installation guidance.
Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables.
1 2 3 4 5 6 7 8 9 10 11 12 14
N N N A A/N N N N N A/N A/N N A
1 2 4 A N S 0 3 6 0 0 0 0A
Product
Family
1 = AC
Tier 2 =
Preferred
SEER
4 = 14
SEER
Variations
S = Side
Discharge
Voltage
N=208/230-1
P=208/230-3
E = 460-3
Variations
S = Standard Cooling Capacity
Open
0 = Not
Defined
Open
0 = Not
Defined
Open
0 = Not
Defined
Series A
=
Original
Series
UNIT SIZE-SERIES (VOLTAGE) 18-A (N)24-A(N) 30-A(N) 36-A (N,P,E) 48-A(N,P,E) 60-A (N,P,E)
Compressor Type Scroll
REFRIGERANT Puron® (R-410A)
Charge lb (kg)6.40 (2.90) 6.50 (2.95) 8.60 (3.90) 8.90 (4.04) 9.00 (4.08) 10.60 (4.81)
Cond Fan Propeller Type, Direct Drive
Air Discharge Horizontal
Air Qty (CFM)1285 1285 1900 2615 2615 2785
Motor HP 1/12 1/12 1/10 1/4 1/4 1/4
Motor RPM 800 800 800 800 800 800
Cond Coil
Face Area (Sq ft)7.3 7.3 12.1 12.1 12.1 14.1
Fin s pe r In. 20 20 20 20 20 20
Rows 2 2 2 2 2 2
Circuits 3 3 3 3 3 4
Valve Connect. (In. ID)
Vapor 5/8 3/4 3/4 7/8 7/8 7/8
Liquid 3/8
Refrigerant Tubes* (In. OD)
Rated Vapor*5/8 3/4 3/4 7/8 7/8 1 1/8
Max Liquid Line 3/8
Use of the AHRI Certified
TM Mark indicates a
manufacturer’s
participation in the
program For verification
of certification for individual
products, go to
www.ahridirectory.org.
PDS124ANS-06 Specifications subject to change without notice. 3
REFRIGERANT PIPING LENGTH LIMITATIONS
Liquid Line Sizing and Maximum Total Equivalent Lengths for Cooling Only Systems with Puron Refrigerant:
The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between the indoor and
outdoor units. Review Maximum Total Equivalent Length Outdoor Unit BELOW Indoor Unit, for the liquid line sizing and maximum
lengths.
Maximum Total Equivalent Length Outdoor Unit BELOW Indoor Unit
* Maximum actual length not to exceed 200 ft (61 m)
Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details.
-- = outside acceptable range
Maximum Total Equivalent Length Outdoor Unit ABOVE Indoor Unit
* Maximum actual length not to exceed 200 ft (61 m)
Total equivalent length accounts for losses due to elbows or fitting. See LONG-LINE APPLICATIONS, for details.
-- = outside acceptable range
SIZE
LIQUID LINE
CONNECTION
(IN. OD)
LIQUID LINE
DIAM.
W/ TXV
(IN. OD)
AC WITH PURON REFRIGERANT MAXIMUM TOTAL EQUIVALENT LENGTH:
OUTDOOR UNIT BELOW INDOOR VERTICAL SEPARATION FT (M)
0-5
(0-1.5)
6-10
(1.8-3.0)
11-20
(3.4-6.1)
21-30
(6.4-9.1)
31-40
(9.4-12.2)
41-50
(12.5-15.2)
51-60
(15.5-18.3)
61-70
(18.6-21.3)
71-80
(21.6-24.4)
018
AC with
Puron
3/8
1/4 150 150 125 100 100 75 -- -- --
5/16 250* 250* 250* 250* 250* 250* 250* 225* 150
3/8 250* 250* 250* 250* 250* 250* 250* 250* 250*
024
AC with
Puron
3/8
1/4 75 75 75 50 50 -- -- -- --
5/16 250* 250* 250* 250* 250* 225* 175 125 100
3/8 250* 250* 250* 250* 250* 250* 250* 250* 250*
030
AC with
Puron
3/8
1/4 30 -- -- -- -- -- -- -- --
5/16 175 225* 200 175 125 100 75 -- --
3/8 250* 250* 250* 250* 250* 250* 250* 250* 250*
036
AC with
Puron
3/8
5/16 175 150 150 100 100 100 75 -- --
3//8 250* 250* 250* 250* 250* 250* 250* 250* 250*
048
AC with
Puron
3/8 3/8 250* 250* 250* 250* 250* 250* 230 160 --
060
AC with
Puron
3/8 3/8 250* 250* 250* 225* 190 150 110 ----
SIZE
LIQUID LINE
CONNECTION
(IN. OD)
LIQUID LINE
DIAM. W/
TXV (IN. OD)
AC WITH PURON REFRIGERANT MAXIMUM TOTAL EQUIVALENT LENGTH:
OUTDOOR UNIT ABOVE INDOOR VERTICAL SEPARATION FT (M)
25
(7.6)
26-50
(7.9-15.2)
51-75
(15.5-22.9)
76-100
(23.2-30.5)
101-125
(30.8-38.1)
126-150
(38.4-45.7)
151-175
(46.0-53.3)
176-200
(53.6-61.0)
018
AC with
Puron
3/8
1/4 175 250*250*250*250*250*250*250*
5/16 250*250*250*250*250*250*250*250*
3/8 250*250*250*250*250*250*250*250*
024
AC with
Puron
3/8
1/4 100 125 175 200 225* 250*250*250*
5/16 250*250*250*250*250*250*250*250*
3/8 250*250*250*250*250*250*250*250*
030
AC with
Puron
3/8
1/4 30 -- -- -- -- -- -- --
5/16 250*250*250*250*250*250*250*250*
3/8 250*250*250*250*250*250*250*250*
036
AC with
Puron
3/8
5/16 225*250*250*250*250*250*250*250*
3/8 250*250*250*250*250*250*250*250*
048
AC with
Puron
3/8 3/8 250*250*250*250*250*250*250*250*
060
AC with
Puron
3/8 3/8 250*250*250*250*250*250*250*250*
4 Specifications subject to change without notice. PDS124ANS-06
REFRIGERANT CHARGE ADJUSTMENTS
Units are factory charged for 15 ft (4.6 m) of 3/8 liquid line. The
factory charge for 3/8 lineset 9 oz (266.16 g). When using other
length or diameter liquid lines, charge adjustments are required per the
REFRIGERANT CHARGE ADJUSTMENTS table.
Charging Formula:
[(Lineset oz/ft x total length) (factory charge for lineset)] =
charge adjustment
Example 1: System has 15 ft of line set using existing 1/4 liquid line.
What charge adjustment is required?
Formula:
(.27 oz/ft x 15ft) (9 oz) = (4.95) oz.
Net result is to remove 4.95 oz of refrigerant from the system
Example 2: System has 45 ft of existing 5/16 liquid line. What is the
charge adjustment?
Formula:
(.40 oz/ft. x 45ft) (9 oz.) = 9 oz.
Net result is to add 9 oz of refrigerant to the system
LONG-LINE APPLICATIONS
An application is considered Long-Line, when the refrigerant level in
the system requires the use of accessories to maintain acceptable
refrigerant management for systems reliability. See ACCESSORY
USAGE GUIDELINES on page 7 for the required accessories.
Defining a system as long-line depends on the liquid line diameter,
actual length of the tubing, and vertical separation between the indoor
and outdoor units.
For air conditioner systems, the AC WITH PURON
REFRIGERANT LONG-LINE DESCRIPTION ft (m) table shows
when an application is considered long-line.
AC WITH PURON REFRIGERANT LONG-LINE DESCRIPTION ft (m)
Beyond these lengths, long line accessories are required
LIQUID LINE SIZE (IN. OD)PURON CHARGE OZ/FT (G/M)
3/8 0.60 (17.74) (Factory charge for lineset = 9 oz / 266.16 g)
5/16 0.40 (11.83)
1/4 0.27 (7.98)
LIQUID LINE SIZE
(IN. OD)UNITS ON SAME LEVEL - FT (M) OUTDOOR BELOW INDOOR - FT (M)OUTDOOR ABOVE INDOOR
- FT (M)
1/4 No accessories needed within allowed lengths No accessories needed within allowed lengths 175 (53.3)
5/16 120 (36.6)50 (15.2) vertical or 120 (36.6) total 120 (36.6)
3/8 80 (24.4)35 (10.7) vertical or 80 24.4) total 80 (24.4)
PDS124ANS-06 Specifications subject to change without notice. 5
VAPOR LINE SIZING AND COOLING CAPACITY LOSS
LONG LINE APPLICATION: An application is considered long-
line when the total equivalent tubing length exceeds 80 ft. (24.4 m) or
when there is more than 20 ft. (6.09 m) vertical separation between the
indoor and outdoor units. These applications require additional
accessories and system modifications for reliable system operation. The
maximum allowable total equivalent length is up to 250 ft. (76.2 m).
The maximum vertical separation is 200 ft. (60.96 m) when the
outdoor unit is above the indoor unit, and up to 80 ft. (24.4 m) when
the outdoor unit is below the indoor unit. Refer to the ACCESSORY
USAGE GUIDELINES on page 7 for required accessories. See the
Long-line Application Guideline for required piping and system
modifications. Also, refer to the Vapor Line Sizing and Cooling
Capacity Losses Puron Refrigerant 1-Stage Air Conditioner
Applications table for the vapor tube diameters based on the total
length to minimize the cooling capacity loss.
Vapor Line Sizing and Cooling Capacity Losses Puron Refrigerant 1-Stage Air Conditioner Applications
*Applications in this area may be long- line and may have height restrictions. See LONG-LINE APPLICATIONS on page 4.
UNIT
NOMINAL
SIZE (BTUH)
MAXIMUM
LIQUID LINE
DIAMETERS
(IN. OD)
VAPOR LINE
DIAMETERS
(IN. OD)
COOLING CAPACITY LOSS (%) TOTAL EQUIVALENT LINE LENGTH FT. (M)
26-50
(7.9-15.2)
51-80
(15.5-24.4)
81-100
(24.7-30.5)
101-125
(30.8-38.1)
126-150
(38.4-45.7)
151-175
(46.0-53.3)
176-200
(53.6-61.0)
201-225
(61.3-68.6)
226-250
(68.9-76.2)
018
1 Stage
AC with
Puron
3/8
1/2 1 2 3 5 6 7 8 9 11
5/8 0 1 1 1 2 2 2 3 3
3/4 0 0 0 0 1 1 1 1 1
024
1 Stage
AC with
Puron
3/8
5/8 0 1 2 2 3 3 4 5 5
3/4 0 0 1 1 1 1 1 2 2
7/8 0 0 0 0 0 1 1 1 1
030
1 Stage
AC with
Puron
3/8
5/8 1 2 3 3 4 5 6 7 8
3/4 0 0 1 1 1 2 2 2 3
7/8 0 0 0 0 1 1 1 1 1
036
1 Stage
AC with
Puron
3/8
5/8 1 2 4 5 6 8 9 10 12
3/4 0 1 1 2 2 3 3 4 4
7/8 0 0 0 1 1 1 1 2 2
048
1 Stage
AC with
Puron
3/8
3/4 0 1 2 3 4 5 5 6 7
7/8 0 0 1 1 2 2 2 3 3
1 1/8 0 0 0 0 0 0 0 1 1
060
1 Stage
AC with
Puron
3/8
3/4 1 2 4 5 6 7 9 10 11
7/8 0 1 2 2 3 4 4 5 5
1 1/8 0 0 0 1 1 1 1 1 1
6 Specifications subject to change without notice. PDS124ANS-06
ACCESSORIES
X = Accessory
ACCESSORY THERMOSTATS
KIT NUMBER KIT NAME
UNIT SIZE (VOLTAGE/SERIES)
018
(30)
024
(30)
030
(30)
036
(30)
036
(50)
036
(60)
048
(30)
048
(50)
048
(60)
060
(30)
060
(50)
060
(60)
KAACH1401AAA Crankcase Heater X X X X X
KAACH1201AAA Crankcase Heater X X X X
KAACH1501AAA Crankcase Heater X
KAACH1901AAA Crankcase Heater X X
KSAFT0101AAA Evaporator Freeze Stat X X X X X X X X X X X X
KAATD0101TDR Time Delay Relay X X X X X X X X X X X X
KAAWS0101AAA Winter Start Kit X X X X X X X X X X X X
KSALA0801AAA Motor Master® 230v X X X X X X X X X
KSALA0901AAA Motor Master® 460v X X X
53DS-900---087 Wind Baffle X X
53DS-900---071 Wind Baffle X X X X X X X
53DS-900---088 Wind Baffle X X X
53DS-900---076 Stacking Kit X X X X X X X X X X X X
53DS-900---077 Wall Mounting Kit X X
53DS-900---078 Wall Mounting Kit X X X X X X X X X X
KAALP0401PUR Low Pressure Switch Kit X X X X X X X X X X X X
KSASH2301COP Sound Blanket Kit X X X X X X
KSASH2401COP Sound Blanket Kit X X X X X X
KAALS0201LLS Solenoid Valve Kit X X X X X X X X X X X X
KSAHS1501AAA Capacitor Relay Start
Assist X X X X X X
PART NUMBER DESCRIPTION
EB-STATE5CR-01 ecobee SmartThermostat Pro with voice control powered by Bryant
EB-STATE3LTCR-01 ecobee3 lite Pro Powered by Bryant
T6-PRH01-A Programmable Relative Humidity Thermostat
T6-PAC01 Programmable Thermostat
T6-NRH01 Non-Programmable Relative Humidity Thermostat
T6-NAC01 Non-Programmable Thermostat
T2-WHS01 WiFi® Thermostat
T2-PAC01 Programmable Thermostat-programmable Thermostat
T2-NAC01 Non-programmable Thermostat
T2-SNAC01 Non-programmable Standard Screen Thermostat
THERMOSTAT ACCESSORIES
T6-EXP edge EXP® Card T6Pxx,T6Nxx
TSTATCCSEN01-B Outdoor Air Temperature Sensor T6-Pxx, T6-Nxx
TSTATXXCNV10 Thermostat Conversion Kit (4 to 5 wire) - 10 pack All Bryant® branded thermostats
TX-MBP01 Medium Decorative Backplate T2-Nxx
TX-LBP01 Large Decorative Backplate T6-Pxx, T6-Nxx, T2-Pxx
PDS124ANS-06 Specifications subject to change without notice. 7
ACCESSORY USAGE GUIDELINES
* For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split-System Long line
Application Guideline.
ACCESSORY DESCRIPTION AND USAGE (LISTED ALPHABETICALLY)
1. Ball−Bearing Fan Motor
A fan motor with ball bearings that permits speed reduction
while maintaining bearing lubrication.
Usage Guideline:
Required on all units when using MotorMaster
2. Compressor Start Assist − Capacitor and Relay
Start capacitor and relay gives a hard boost to compressor
motor at each start up.
Usage Guideline:
Required for reciprocating compressors in the following
applications:
Long line
Low ambient cooling
Hard shut off expansion valve on indoor coil
Liquid line solenoid on indoor coil
Required for single−phase scroll compressors in the
following applications:
Long line
Low ambient cooling
Suggested for all compressors in areas with a history of
low voltage problems.
3. Crankcase Heater
An electric resistance heater which mounts to the base of the
compressor to keep the lubricant warm during off cycles.
Improves compressor lubrication on restart and minimizes the
chance of liquid slugging.
Usage Guideline:
Required in low ambient cooling applications.
Required in long line applications.
Suggested in all commercial applications.
4. Evaporator Freeze Thermostat
An SPST temperature−actuated switch that stops unit operation
when the evaporator reaches freeze−up conditions.
Usage Guideline:
Required when a low ambient kit has been added.
5. Low Pressure Switch Kit
Optional added compressor protection against loss of
refrigerant. The compressor cuts out the system at 50 PSI and
allows operation again at 95 PSI. Used for commercial or
harsh environment applications for extra protection. Not
required for a Low−Ambient Cooling application.
6. MotorMaster Low−Ambient Controller
A fan−speed control device activated by a temperature sensor,
designed to control condenser fan motor speed in response to
saturated condensing temperatures down to −20 F (−28.9 C), it
maintains condensing temperature at 100 F +/ − 10 F (37.8 C +/
− 6 C).
Usage Guideline:
A MotorMaster Low−Ambient Controller must be used when
the cooling operation is used at outdoor temperatures below
55 F (12.8 C). Suggested for all commercial applications.
7. Winter Start Kit
The device is designed to alleviate nuisance opening of the
low−pressure switch by bypassing it for the first 3 minutes of
operation. A Winter Start control must be used where low
evaporator temperatures, or nuisance tripping of low−pressure
switch may be encountered. It is not required for low ambient
cooling applications unless a low−pressure switch
KAALP0401PUR is added.
8. Time Delay Relay
Optional accessory for systems that do not have an integral
blower time delay.
ACCESSORY
REQUIRED FOR LOW-AMBIENT
COOLING APPLICATIONS
(BELOW 55 F / 12.8 C)
REQUIRED FOR
LONG LINE APPLICATIONS*
(OVER 80 FT. / 24.38 M)
REQUIRED FOR
SEA COAST APPLICATIONS
(WITHIN 2 MILES / 3.22 KM)
Ball Bearing Fan Motor Standard Standard Standard
Compressor Start Assist
Capacitor and Relay Yes Yes No
Crankcase Heater Yes Yes No
Evaporator Freeze Thermostat Yes No No
Liquid Line Solenoid Valve No See Long-Line Application Guideline No
Motor Master® Controller Yes No No
8 Specifications subject to change without notice. PDS124ANS-06
ELECTRICAL DATA
LEGEND:
FLA - Full Load Amps
HACR - Heating, Air Conditioning, Refrigeration
LRA - Locked Rotor Amps
NEC - National Electrical Code
RLA - Rated Load Amps (compressor)
* Permissible limits of the voltage range at which the unit operates satisfactorily
** Time-Delay fuse.
Complies with 2007 requirements of ASHRAE Standards 90.1
A−WEIGHTED SOUND POWER (dBA)
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI).
A−WEIGHTED SOUND POWER (dBA) WITH ACCESSORY SOUND SHIELD
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI).
SOUND PRESSURE LEVELS, (dBA)
NOTE: Sound pressure data vs distance converted using AHRI 275 Standard under certain environmental and layout assumptions .
CHARGING SUB−COOLING (TXV−TYPE EXPANSION DEVICE
NOTE: The conversion is accurate only when all the assumptions are correct.
UNIT SIZE -
VOLTAGE, SERIES V/PH OPER VOLTS*COMPR FAN MCA MAX FUSE** OR
CKT BRK AMPSMAX MIN LRA RLA FLA
18-30
208/230/1 253 197
56.3 9.0 0.50 11.8 20
24-30 62.9 10.9 0.50 14.1 25
30-30 73.0 14.1 0.70 18.3 30
36-30 77.0 14.1 1.20 18.8 30
48-30 124.0 18.5 1.20 24.3 40
60-30 152.5 23.7 1.45 31.1 50
36-50
208/230/3 253 197
71.0 9.0 1.20 12.5 20
48-50 83.1 13.7 1.20 18.3 30
60-50 110.0 15.9 1.45 21.4 35
36-60
460/3 506 414
38.0 5.6 0.60 7.6 15
48-60 41.0 6.2 0.60 8.4 15
60-60 52.0 7.1 0.80 9.7 15
UNIT SIZE STANDARD RATING (DBA)TYPICAL OCTAVE BAND SPECTRUM (DBA, WITHOUT TONE ADJUSTMENT)
125 250 500 1000 2000 4000 8000
18 69 50.5 57.0 59.5 64.5 60.5 53.5 43.0
24 66 50.5 58.5 60.5 59.5 56.5 51.0 41.5
30 68 55.5 59.5 61.5 63.5 60.0 58.0 49.5
36 71 59.5 59.5 62.0 65.5 63.5 62.0 55.0
48 70 57.5 59.5 64.0 66.0 63.0 60.5 54.5
60 73 60.0 61.5 64.5 67.0 66.0 65.5 58.0
UNIT SIZE STANDARD RATING (DBA)TYPICAL OCTAVE BAND SPECTRUM (DBA, WITHOUT TONE ADJUSTMENT)
125 250 500 1000 2000 4000 8000
18 68 52.5 58.0 58.5 64.5 59.5 52.5 42.5
24 65 54.5 57.5 59.5 59.0 56.0 50.5 40.5
30 68 55.0 60.0 61.5 62.5 60.0 58.0 49.5
36 71 59.5 59.5 62.5 65.0 63.0 61.5 55.0
48 70 57.5 59.5 63.0 65.0 62.5 60.0 54.0
60 73 61.0 62.0 64.0 67.0 65.5 65.5 57.5
UNIT SIZE AT DISTANCE 10' FROM UNIT AT DISTANCE 15' FROM UNIT AT DISTANCE 20' FROM UNIT
18 51.5 48.0 45.5
24 48.5 45.0 42.5
30 50.5 47.0 44.5
36 53.5 50.0 47.5
48 52.5 49.0 46.5
60 55.5 52.0 49.5
UNIT SIZE-SERIES REQUIRED SUBCOOLING °F (°C)
18 12 (6.7)
24 12 (6.7)
30 12 (6.7)
36 8 (4.4)
48 12 (6.7)
60 10 (5.6)
PDS124ANS-06 Specifications subject to change without notice. 9
DIMENSIONS-ENGLISH
Fig. 2 Dimensions
1. Clearance Requirements:
a. Single Unit Applications:
With the coil facing the wall, allow 6in (152mm) minimum
clearance on the coil side, the coil end, and allow 20in (508mm)
minimum clearance on the fan side.
With the fan facing the wall, allow 8in (203mm) minimum
clearance on the fan side, 6in (152mm) on the coil end and 20in
(508mm) minimum clearance on the coil side.
b. Multi Unit Applications:
Allow 24in (610mm) minimum clearance between the fan and the
coil sides of the multiple units. Arrange the units so the discharge
of one unit does not enter the inlet of the other unit. When two
units are installed end to end with the coil ends facing each other
allow 12in (305mm) in minimum clearance between the units.
c. Compressor End Service Clearance:
Allow 24in (610mm) minimum clearance on the compressor end
when the units are stacked or there is less than 40 in. (1016mm) of
clearance above the top of the unit. If there is 40 in. (1016mm) of
clearance above the unit and top panel is accessible for removal,
allow 8in (203mm) minimum clearance minimum clearance on the
compressor end for service.
IMPORTANT: When installing single or multiple units in an alcove,
roof well, or partially enclosed area, ensure there is adequate ventilation to
prevent recirculation of discharged air.
2. Minimum outdoor operating ambient in the COOLING mode is
55 F (13 C) and a maximum of 125 F (52 C).
3. Series designation is the 13th position of the unit model number
4. Center of gravity
5. All dimensions are in inches unless noted.
Fig. 3 Dimensions
UNIT Series Electrical
Characteristics A B C D E F G H J K L M N P
Operating
Weight
(lbs)
Shipping
Weight
(lbs)
Shipping Dimensions
(L x W x H)
124ANS018 0 X 0 0 0 31 1/8 36 15/16 14 9/16 16 23 7/16 17 3/16 23 1/8 28 1/16 13 6 5/8 11 1/4 5/8 2 7/8 5 13/16 146 166 42 15/16 x 18 x 34 1/8
124ANS024 0 X 0 0 0 31 1/8 36 15/16 14 9/16 16 23 7/16 17 3/16 23 1/8 28 1/16 14 6 3/4 11 5/8 3/4 2 7/8 5 13/16 148 168 42 15/16 x 18 x 3 4 1/8
124ANS030 0 X 0 0 0 37 1/8 44 1/2 17 1/16 18 7/16 30 1/2 19 5/8 29 1/8 34 1/16 13 11/16 8 1/8 15 7/8 3/4 3 3/8 6 3/8 183 213 50 1/2 x 20 1/2 x 40 1/8
124ANS036 0 X 0 X X 37 1/8 44 1/2 17 1/16 18 7/16 30 1/2 19 5/8 29 1/8 34 1/16 13 11/16 8 1/8 15 7/8 7/8 3 3/8 6 3/8 184 214 50 1/2 x 20 1/2 x 40 1/8
124ANS048 0 X 0 X X 37 1/8 44 1/2 17 1/16 18 7/16 30 1/2 19 5/8 29 1/8 34 1/16 14 1/2 8 1/2 18 7/8 7/8 3 3/8 6 3/8 213 243 50 1/2 x 20 1/2 x 40 1/8
124ANS060 0 X 0 X X 43 1/8 44 1/2 17 1/16 18 7/16 30 1/2 19 5/8 35 1/8 40 1/16 14 1/2 8 1/2 18 7/8 7/8 3 3/8 6 3/8 245 275 50 1/2 x 20 1/2 x 46 1/8
20
8
-
2
3
0
-
1
-
6
0
20
3
-
1
-
6
0
20
8
/
2
3
0
-
3
-
6
0
46
0
-
3
-
6
0
X = YES
0 = NO
AIR
7 1/2” 2 1/2”
4 3/16”
AIR
11/16”
FIELD CONTROL SUPPLY
WIRE ENTRY
7/8” HOLE W/GROMMET
M VAPOR LINE CONN.
FEMALE SWEAT CONN.
JUNCTION BOX FOR
POWER SUPPLY AND
CONTROL CONNECTIONS
3/8’ LIQUID LINE
FEMALE SWEAT CONN.
1 7/16”
8 1/16”
1 7/16”
4 1/12”1”
FIELD POWER SUPPLY CONN
HOLE SIZES PROVIDED:
7/8” HOLD WITH
1 1/8” KNOCKOUT AND
1 3/8” KNOCKOUT
UNIT SIZE MINIMUM MOUNTING
PAD DIMENSIONS
18,24 23 x 42
30,36,48,60 24 x 50
10 Specifications subject to change without notice. PDS124ANS-06
DIMENSIONS-SI
Fig. 4 Dimensions
1. Clearance Requirements:
a. Single Unit Applications:
With the coil facing the wall, allow 6in (152.4mm) minimum
clearance on the coil side, the coil end and allow 20in (508mm)
minimum clearance on the fan side. With the fan facing the wall
allow 8in (203.2mm) minimum clearance on the fan side and 6in
(152.4mm) on the coil end plus 20in (504.0mm) minimum
clearance on the coil side.
b. Multi Unit Applications:
Allow 24in (609.6mm) minimum clearance between the fan and
coil sides of the multiple units. Arrange the units so the discharge
of one does not enter the inlet of another. When two units are
installed end to end with the coil ends facing each other, allow 12in
(304.8 mm) minimum clearance between the units.
c. Compressor End Service Clearance:
Allow 24in (609.6mm) minimum clearance on the compressor end
when the units are stacked or there is less than 40in (1016mm) of
clearance above the top of the unit. If there is 40in (1016mm)
clearance above the unit and the top panel is accessible for
removal, allow 8in (203.2mm) minimum clearance on the
compressor end for service.
IMPORTANT: When installing single or multiple units in
an alcove, roof well, or partially enclosed area, ensure there
is adequate ventilation to prevent recirculation of
discharged air.
2. Minimum outdoor operating ambient in the COOLING mode is
12.8 F (12.8 C) and a maximum of 125 F (51.7 C)
3. Series designation is the 14th position of the unit model number
4. Center of gravity
5. All dimensions are in millimeters unless noted.
Fig. 5 Dimensions
UNIT Series Electrical
Characteristics A B C D E F G H J K L M N P
Operating
Weight
(KG)
Shipping
Weight
(KG)
Shipping Dimensions
(L x W x H)
124ANS018 0 X 0 0 0 790.4 938.0 370.0 406.0 595.5 436.0 587.6 712.2 330.2 168.3 285.8 15.9 73.0 148.2 66.2 75.3 1090.2 x 45.7 x 866.7
124ANS024 0 X 0 0 0 790.4 938.0 370.0 406.0 595.5 436.0 587.6 712.2 355.5 171.5 295.3 19.1 73.0 148.2 67.1 76.2 1090.2 x 45.7 x 866.7
124ANS030 0 X 0 0 0 942.8 1130.0 433.0 469.0 774.5 499.0 740.0 864.6 347.7 206.4 403.2 19.1 86.0 161.2 83.0 96.6 1282.7 x 520.7 x 1019.1
124ANS036 0 X 0 X X 942.8 1130.0 433.0 469.0 774.5 499.0 740.0 864.6 347.7 206.4 403.2 22.2 86.0 161.2 83.5 97.1 1282.7 x 520.7 x 1019.1
124ANS048 0 X 0 X X 942.8 1130.0 433.0 469.0 774.5 499.0 740.0 864.6 368.3 215.9 479.4 22.2 86.0 161.2 96.6 110.2 1282.7 x 520.7 x 1019.1
124ANS060 0 X 0 X X 1095.2 1130.0 433.0 469.0 774.5 499.0 892.4 1,017.0 368.3 215.9 479.4 22.2 86.0 161.2 245 124.7 1282.7 x 520.7 x 1717.5
20
8
-
2
3
0
-
1
-
6
0
20
3
-
1
-
6
0
20
8
/
2
3
0
-
3
-
6
0
46
0
-
3
-
6
0
AIR
AIR
190.5 63.6
106.3
18.0
FIELD POWER SUPPLY CONN.
HOLE SIZES PROVIDED:
22.23 HOLD WITH
28.58 KNOCKOUT AND
34.93 KNOCKOUT
JUNCTION BOX FOR
POWER SUPPLY AND
CONTROL CONNECTIONS
36.2
36.6
204.1
114.325.0
FIELD CONTROL SUPPLY
WIRE ENTRY
22.22 HOLE W/GROMMET
M VAPOR LINE CONN.
FEMALE SWEAT CONN.
9.53 LIQUID LINE
FEMALE SWEAT CONN.
UNIT SIZE MINIMUM MOUNTING
PAD DIMENSIONS
18,24 584.2 x 1066.8
30,36,48,60 609.6 x 1270.0
PDS124ANS-06 Specifications subject to change without notice. 11
TESTED AHRI COMBINATION RATINGS*
NOTE: Ratings contained in this document are subject to change at any time.
For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org.
Additional ratings and system combinations can be accessed via the Bryant database at: www.MyBryantRatings.com.
For performance data at specific application &/or design conditions with various indoor unit combinations, the equipment performance
calculator can be accessed at: http://rpmob.wrightsoft.com/.
EER Energy Efficiency Ratio
SEER Seasonal Energy Efficiency Ratio
TXV Thermostatic Expansion Valve
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other
combinations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in the fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are significantly affected.
Outdoor Model Number -
Series (voltage)Indoor Coil Model Number Furnace Model Number Capacity EER SEER
124ANS018-A (N) CNPV*3014AL*+TDR 18,000 12.2 14
124ANS024-A (N) CNPV*3117AL*+TDR 24,000 12.2 14
124ANS030-A (N) CNPV*3117AL*+TDR 29,600 12.2 14
124ANS036-A (N,P,E) CNPV*3717AL*+TDR 35,400 12.2 14
124ANS048-A (N,P,E) CNPV*6024AL*+TDR 45,000 12.2 14
124ANS060-A (N,P,E) CNPV*6124AL*+TDR 57,000 11.7 14
12 Specifications subject to change without notice. PDS124ANS-06
DETAILED COOLING CAPACITIES
See the notes on page 13.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F (°C)
75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125
(51.7)
CFM EWB
°F (°C)
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**Total Sens Total Sens Total Sens Total Sens Total Sens Total Sens
124ANS018-A Outdoor Section With CNPV*3014AL* Indoor Section
525
72 (22.2) 21.49 10.92 1.18 20.55 10.57 1.31 19.56 10.21 1.45 18.50 9.83 1.61 17.36 9.43 1.79 16.12 9.00 2.00
67 (19.4) 19.43 13.31 1.18 18.58 12.96 1.31 17.67 12.60 1.45 16.71 12.22 1.61 15.68 11.82 1.79 14.57 11.39 2.00
63 (17.2) 17.96 12.78 1.18 17.15 12.43 1.31 16.31 12.06 1.45 15.43 11.69 1.61 14.48 11.29 1.79 13.46 10.86 2.00
62 (16.7) 17.68 15.68 1.18 16.91 15.33 1.31 16.11 14.96 1.45 15.28 14.56 1.61 14.48 14.48 1.79 13.65 13.65 2.00
57 (13.9) 17.17 17.17 1.18 16.55 16.55 1.31 15.91 15.91 1.45 15.21 15.21 1.61 14.46 14.46 1.79 13.63 13.63 2.00
600
72 (22.2) 21.93 11.50 1.21 20.94 11.14 1.34 19.90 10.77 1.48 18.79 10.38 1.64 17.61 9.97 1.82 16.32 9.53 2.03
67 (19.4) 19.84 14.22 1.21 18.94 13.87 1.34 18.00 13.50 1.48 17.00 13.11 1.63 15.93 12.70 1.82 14.78 12.26 2.03
63 (17.2) 18.34 13.63 1.21 17.51 13.27 1.33 16.63 12.90 1.47 15.70 12.51 1.63 14.72 12.10 1.82 13.65 11.66 2.03
62 (16.7) 18.14 16.91 1.21 17.36 16.53 1.33 16.61 16.61 1.47 15.86 15.86 1.63 15.05 15.05 1.82 14.15 14.15 2.03
57 (13.9) 17.95 17.95 1.21 17.29 17.29 1.33 16.59 16.59 1.47 15.84 15.84 1.63 15.02 15.02 1.82 14.13 14.13 2.03
675
72 (22.2) 22.25 12.05 1.24 21.22 11.69 1.36 20.15 11.31 1.50 19.00 10.91 1.66 17.78 10.50 1.85 16.46 10.05 2.06
67 (19.4) 20.15 15.11 1.24 19.22 14.74 1.36 18.25 14.37 1.50 17.22 13.97 1.66 16.12 13.55 1.85 14.94 13.09 2.06
63 (17.2) 18.64 14.45 1.24 17.77 14.08 1.36 16.86 13.70 1.50 15.91 13.30 1.66 14.90 12.88 1.84 13.81 12.42 2.05
62 (16.7) 18.63 18.63 1.24 17.92 17.92 1.36 17.18 17.18 1.50 16.38 16.38 1.66 15.51 15.51 1.84 14.56 14.56 2.06
57 (13.9) 18.60 18.60 1.24 17.89 17.89 1.36 17.15 17.15 1.50 16.36 16.36 1.66 15.49 15.49 1.84 14.55 14.55 2.06
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F (°C)
75 °F (23.9°C)85 °F (29.4°C)95 °F (35°C) 105 °F (40.6°C) 115 °F (46.1°C)125 °F (51.7°C)
CFM EWB
°F (°C)
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**Total Sens Total Sens Total Sens Total Sens Total Sens Total Sens
124ANS024 - A Outdoor Section With CNPV*3117AL* Indoor Section
700
72 (22.2) 28.62 14.23 1.58 27.33 13.77 1.75 25.95 13.30 1.94 24.48 12.80 2.15 22.90 12.26 2.40 21.21 11.70 2.67
67 (19.4) 26.06 17.53 1.57 24.88 17.08 1.74 23.63 16.60 1.93 22.30 16.09 2.14 20.87 15.56 2.39 19.33 14.99 2.67
63 (17.2) 24.20 16.87 1.57 23.11 16.41 1.74 21.96 15.94 1.92 20.73 15.44 2.14 19.41 14.91 2.38 17.99 14.34 2.66
62 (16.7) 23.80 20.79 1.57 22.74 20.32 1.73 21.65 19.83 1.92 20.58 20.58 2.14 19.51 19.51 2.38 18.33 18.33 2.66
57 (13.9) 23.29 23.29 1.57 22.44 22.44 1.73 21.53 21.53 1.92 20.55 20.55 2.14 19.48 19.48 2.38 18.31 18.31 2.66
800
72 (22.2) 29.11 14.99 1.62 27.76 14.53 1.79 26.33 14.04 1.98 24.80 13.53 2.19 23.16 12.99 2.43 21.41 12.42 2.71
67 (19.4) 26.53 18.75 1.61 25.30 18.29 1.78 24.00 17.80 1.97 22.61 17.28 2.18 21.13 16.74 2.43 19.54 16.16 2.70
63 (17.2) 24.68 18.01 1.61 23.53 17.54 1.77 22.33 17.06 1.96 21.05 16.55 2.18 19.67 16.00 2.42 18.21 15.42 2.70
62 (16.7) 24.39 22.42 1.61 23.40 23.40 1.77 22.42 22.42 1.96 21.36 21.36 2.18 20.20 20.20 2.42 18.94 18.94 2.70
57 (13.9) 24.28 24.28 1.61 23.36 23.36 1.77 22.39 22.39 1.96 21.32 21.32 2.18 20.17 20.17 2.42 18.91 18.91 2.70
900
72 (22.2) 29.46 15.72 1.66 28.07 15.25 1.83 26.59 14.76 2.01 25.01 14.24 2.23 23.33 13.69 2.47 21.53 13.11 2.75
67 (19.4) 26.88 19.93 1.65 25.61 19.46 1.82 24.27 18.96 2.01 22.84 18.43 2.22 21.32 17.87 2.46 19.70 17.27 2.74
63 (17.2) 25.04 19.11 1.65 23.85 18.63 1.81 22.60 18.14 2.00 21.28 17.61 2.21 19.87 17.05 2.46 18.38 16.43 2.74
62 (16.7) 25.15 25.15 1.65 24.16 24.16 1.81 23.11 23.11 2.00 21.98 21.98 2.22 20.75 20.75 2.46 19.42 19.42 2.74
57 (13.9) 25.11 25.11 1.65 24.13 24.13 1.81 23.08 23.08 2.00 21.95 21.95 2.22 20.73 20.73 2.46 19.29 19.39 2.74
PDS124ANS-06 Specifications subject to change without notice. 13
DETAILED COOLING CAPACITIES (CONT.)
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F (°C)
75°F (23.9°C)85°F (29.4°C)95°F (35°C)105°F (40.6°C)115°F (46.1°C)125°F (51.7°C)
CFM EWB
°F (°C)
Capacity MBtuh Total
System
KW**
Capacity MBtuh Total
System
KW**
Capacity MBtuh Total
System
KW**
Capacity MBtuh Total
System
KW**
Capacity MBtuh Total
System
KW**
Capacity MBtuh Total
System
KW** Total Sens Total Sens Total Sens Total Sens Total Sens Total Sens
124ANS030-A Outdoor Section With CNPV*3117AL* Indoor Section
875
72 (22.2) 35.20 16.84 1.95 33.62 16.29 2.18 31.97 15.73 2.43 30.18 15.13 2.70 28.24 14.48 3.02 26.13 13.79 3.38
67 (19.4) 31.99 20.62 1.92 30.56 20.08 2.15 29.06 19.51 2.40 27.44 18.91 2.68 25.67 18.26 3.00 23.75 17.57 3.36
63 (17.2) 29.66 19.84 1.90 28.34 19.30 2.13 26.95 18.74 2.37 25.45 18.13 2.66 23.80 17.48 2.98 22.02 16.78 3.35
62 (16.7) 29.18 24.36 1.90 27.92 23.82 2.12 26.58 23.24 2.37 25.18 24.97 2.65 23.81 23.81 2.98 22.34 22.34 3.35
57 (13.9) 28.38 28.38 1.89 27.37 27.37 2.12 26.28 26.28 2.37 25.09 25.09 2.65 23.77 23.77 2.98 22.31 22.31 3.35
1000
72 (22.2) 35.90 17.73 1.98 34.26 17.17 2.21 32.52 16.59 2.46 30.66 15.98 2.74 28.65 15.32 3.05 26.46 14.62 3.41
67 (19.4) 32.65 22.03 1.95 31.17 21.48 2.18 29.60 20.90 2.43 27.91 20.28 2.71 26.08 19.62 3.03 24.10 18.91 3.39
63 (17.2) 30.30 21.15 1.93 28.93 20.60 2.16 27.48 20.02 2.40 25.91 19.41 2.69 24.21 18.74 3.01 22.36 18.02 3.37
62 (16.7) 29.94 26.26 1.93 28.66 25.66 2.15 27.43 27.43 2.41 26.15 26.15 2.69 24.73 24.73 3.01 23.17 23.17 3.38
57 (13.9) 29.65 29.65 1.93 28.56 28.56 2.15 27.39 27.39 2.40 26.11 26.11 2.69 24.70 24.70 3.01 23.14 23.14 3.38
1125
72 (22.2) 36.44 18.57 2.01 34.73 18.00 2.24 32.94 17.41 2.49 31.02 16.79 2.77 28.94 16.12 3.08 26.71 15.41 3.43
67 (19.4) 33.18 23.38 1.98 31.64 22.82 2.21 30.01 22.23 2.46 28.28 21.60 2.74 26.40 20.92 3.05 24.38 20.18 3.41
63 (17.2) 30.81 22.41 1.96 29.38 21.85 2.19 27.89 21.26 2.43 26.28 20.63 2.72 24.53 19.94 3.04 22.65 19.20 3.40
62 (16.7) 30.76 30.76 1.96 29.59 29.59 2.19 28.34 28.34 2.44 26.99 26.99 2.72 25.49 25.49 3.05 23.84 23.84 3.41
57 (13.9) 30.72 30.72 1.96 29.55 29.55 2.19 28.31 28.31 2.44 26.95 26.95 2.72 25.45 25.45 3.04 23.81 23.81 3.41
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F (°C)
75°F (23.9°C)85°F (29.4°C)95°F (35°C)105°F (40.6°C)115°F (46.1°C)125°F (51.7°C)
CFM EWB
°F (°C)
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**Total Sens Total Sens Total Sens Total Sens Total Sens Total Sens
124ANS036-A Outdoor Section With CNPV*3717AL* Indoor Section
1050
72 (22.2) 42.58 22.26 2.36 40.51 21.51 2.60 38.30 20.71 2.87 35.94 19.87 3.16 33.37 18.97 3.50 30.62 18.01 3.88
67 (19.4) 38.73 27.46 2.34 36.87 26.71 2.58 34.88 25.92 2.84 32.74 25.08 3.14 30.43 24.18 3.48 27.97 23.23 3.86
63 (17.2) 35.96 26.41 2.32 34.24 25.67 2.56 32.40 24.88 2.82 30.43 24.04 3.12 28.31 23.15 3.46 26.03 22.20 3.85
62 (16.7) 35.38 32.60 2.32 33.73 31.84 2.56 32.01 31.81 2.82 30.38 30.38 3.12 28.63 28.63 3.46 26.73 26.73 3.85
57 (13.9) 34.71 34.71 2.31 33.37 33.37 2.55 31.92 31.92 2.82 30.34 30.34 3.12 28.59 28.59 3.46 26.70 26.70 3.85
1200
72 (22.2) 43.29 23.46 2.42 41.13 22.69 2.66 38.84 21.88 2.93 36.37 21.02 3.22 33.71 20.10 3.56 30.85 19.13 3.94
67 (19.4) 39.43 29.38 2.40 37.47 28.61 2.64 35.40 27.80 2.90 33.18 26.94 3.20 30.79 26.02 3.53 28.26 25.05 3.92
63 (17.2) 36.64 28.20 2.38 34.83 27.43 2.62 32.92 26.62 2.88 30.87 25.77 3.18 28.67 24.85 3.52 26.33 23.88 3.91
62 (16.7) 36.27 36.05 2.38 34.77 34.77 2.62 33.20 33.20 2.89 31.50 31.50 3.19 29.61 29.61 3.53 27.57 27.57 3.92
57 (13.9) 36.17 36.17 2.38 34.71 34.71 2.62 33.15 33.15 2.89 31.45 31.45 3.19 29.57 29.57 3.53 27.54 27.54 3.91
1350
72 (22.2) 43.81 24.60 2.48 41.58 23.82 2.72 39.20 23.00 2.99 36.66 22.13 3.28 33.92 21.20 3.62 31.04 20.23 4.00
67 (19.4) 39.93 31.22 2.46 37.92 30.44 2.70 35.78 29.61 2.96 33.50 28.73 3.26 31.06 27.78 3.59 28.49 26.76 3.98
63 (17.2) 37.14 29.91 2.44 35.28 29.13 2.68 33.30 28.30 2.94 31.20 27.42 3.24 28.94 26.47 3.58 26.58 25.43 3.97
62 (16.7) 37.43 37.43 2.44 35.87 35.87 2.68 34.21 34.21 2.95 32.39 32.39 3.25 30.39 30.39 3.59 28.23 28.23 3.98
57 (13.9) 37.38 37.38 2.44 35.83 35.83 2.68 34.16 34.16 2.95 32.35 32.35 3.25 30.36 30.36 3.59 28.20 28.20 3.98
14 Specifications subject to change without notice. PDS124ANS-06
DETAILED COOLING CAPACITIES (CONT.)
Total and sensible capacities are net capacities. Blower mower hear has been subtracted.
Sensible capacities shown are based on 80F (27C) entering air at the indoor coil. For sensible capacities at other than 80F (27C), deduct 835 Btuh
(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80F (27C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80F (27C).
** System kw is total of indoor and outdoor unit kilowatts.
EWB Entering Wet Bulb
NOTES:
1. Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240-2008. If additional tubing
length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.
2. When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F (°C)
75°F (23.9°C)85°F (29.4°C)95°F (35°C)105°F (40.6°C)115°F (46.1°C)125°F (51.7°C)
CFM EWB
°F (°C)
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**Total Sens Total Sens Total Sens Total Sens Total Sens Total Sens
124ANS048-A Outdoor Section With CNPV*6024AL* Indoor Section
1400
72 (22.2) 54.32 28.47 3.22 51.89 27.57 3.53 49.29 26.62 3.88 46.43 25.59 4.29 43.30 24.47 4.76 39.89 23.27 5.30
67 (19.4) 49.54 35.14 3.19 47.35 34.25 3.49 45.00 33.30 3.85 42.43 32.28 4.25 39.60 31.16 4.72 36.51 29.95 5.26
63 (17.2) 46.06 33.82 3.16 44.05 32.94 3.47 41.89 32.00 3.82 39.52 30.98 4.22 36.90 29.87 4.69 34.04 28.66 5.23
62 (16.7) 45.44 41.73 3.15 43.53 40.82 3.46 41.48 39.82 3.81 39.37 39.37 4.22 37.22 37.22 4.70 34.80 34.80 5.24
57 (13.9) 44.54 44.54 3.15 42.97 42.97 3.46 41.24 41.24 3.81 39.32 39.32 4.22 37.17 37.17 4.70 34.76 34.76 5.24
1600
72 (22.2) 55.17 29.90 3.30 52.64 28.99 3.61 49.92 28.01 3.96 46.96 26.96 4.37 43.72 25.83 4.84 40.19 24.61 5.38
67 (19.4) 50.36 37.46 3.27 48.09 36.55 3.57 45.64 35.59 3.93 42.97 34.53 4.34 40.05 33.39 4.81 36.86 32.13 5.34
63 (17.2) 46.86 35.98 3.24 44.77 35.09 3.55 42.51 34.12 3.90 40.05 33.08 4.31 37.35 31.93 4.77 34.40 30.67 5.31
62 (16.7) 46.51 44.79 3.24 44.64 44.64 3.55 42.79 42.79 3.90 40.73 40.73 4.31 38.42 38.42 4.79 35.83 35.83 5.33
57 (13.9) 46.30 46.30 3.24 44.60 44.60 3.55 42.73 42.73 3.90 40.67 40.67 4.31 38.37 38.37 4.79 35.79 35.79 5.33
1800
72 (22.2) 55.79 31.25 3.38 53.16 30.32 3.69 50.36 29.34 4.04 47.31 28.27 4.45 43.97 27.12 4.92 40.37 25.89 5.46
67 (19.4) 50.98 39.68 3.35 48.62 38.75 3.65 46.10 37.76 4.01 43.37 36.69 4.42 40.37 35.50 4.89 37.14 34.18 5.42
63 (17.2) 47.47 38.04 3.32 45.30 37.12 3.63 42.98 36.13 3.98 40.45 35.06 4.39 37.69 33.87 4.86 34.70 32.54 5.39
62 (16.7) 47.80 47.80 3.32 45.99 45.99 3.63 44.00 44.00 3.99 41.81 41.81 4.40 39.36 39.36 4.88 36.64 36.64 5.42
57 (13.9) 47.74 47.74 3.32 45.93 45.93 3.63 43.95 43.95 3.99 41.76 41.76 4.40 39.32 39.32 4.87 36.60 36.60 5.41
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F (°C)
75°F (23.9°C)85°F (29.4°C)95°F (35°C)105°F (40.6°C)115°F (46.1°C)125°F (51.7°C)
CFM EWB
°F (°C)
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Capacity MBtuh Total
Sys
KW**
Total Sens Total Sens Total Sens Total Sens Total Sens Total Sens
124ANS060-A Outdoor Section With CNPV*6124AL* Indoor Section
1750
72 (22.2) 68.86 34.68 4.09 65.73 33.57 4.48 62.37 32.40 4.93 58.68 31.12 5.45 54.65 29.75 6.04 50.21 28.26 6.71
67 (19.4) 62.81 42.85 4.03 60.01 41.76 4.42 57.00 40.60 4.87 53.69 39.34 5.39 50.05 37.96 5.98 46.03 36.46 6.65
63 (17.2) 58.41 41.24 3.99 55.85 40.17 4.38 53.11 39.03 4.82 50.06 37.78 5.34 46.70 36.41 5.93 42.98 34.90 6.59
62 (16.7) 57.61 50.93 3.98 55.17 49.82 4.37 52.58 48.59 4.82 49.93 49.93 5.34 47.15 47.15 5.94 44.00 44.00 6.61
57 (13.9) 56.53 56.53 3.97 54.53 54.53 4.37 52.32 52.32 4.82 49.86 49.86 5.34 47.09 47.09 5.94 43.94 43.94 6.61
2000
72 (22.2) 69.94 36.44 4.19 66.66 35.31 4.58 63.14 34.10 5.04 59.32 32.81 5.56 55.14 31.41 6.15 50.56 29.90 6.81
67 (19.4) 63.84 45.70 4.14 60.93 44.59 4.53 57.78 43.40 4.98 54.34 42.10 5.49 50.59 40.69 6.08 46.45 39.14 6.75
63 (17.2) 59.43 43.90 4.09 56.76 42.80 4.48 53.87 41.62 4.93 50.72 40.34 5.44 47.25 38.93 6.03 43.42 37.37 6.70
62 (16.7) 58.98 54.67 4.09 56.66 56.66 4.48 54.28 54.28 4.94 51.61 51.61 5.46 48.63 48.63 6.06 45.27 45.27 6.73
57 (13.9) 58.76 58.76 4.09 56.58 56.58 4.48 54.20 54.20 4.93 51.55 51.55 5.46 48.57 48.57 6.05 45.22 45.22 6.73
2250
72 (22.2) 70.70 38.10 4.29 67.30 36.94 4.68 63.68 35.72 5.14 59.73 34.41 5.66 55.44 32.99 6.25 50.77 31.46 6.91
67 (19.4) 64.61 48.42 4.24 61.59 47.28 4.63 58.35 46.06 5.08 54.82 44.74 5.59 50.98 43.27 6.18 46.79 41.64 6.85
63 (17.2) 60.18 46.42 4.19 57.41 45.29 4.58 54.45 44.09 5.03 51.21 42.77 5.55 47.66 41.31 6.13 43.79 39.65 6.80
62 (16.7) 60.66 60.66 4.20 58.34 58.34 4.59 55.79 55.79 5.05 52.96 52.96 5.57 49.81 49.81 6.17 46.25 46.25 6.84
57 (13.9) 60.58 60.58 4.20 58.27 58.27 4.59 55.72 55.72 5.05 52.90 52.90 5.57 49.75 49.75 6.17 46.20 46.20 6.84
PDS124ANS-06 Specifications subject to change without notice. 15
CONDENSER ONLY RATINGS
See notes on page 15.
SST °F (°C)CONDENSER ENTERING AIR TEMPERATURES °F (°C)
55 °F (12.78°C) 65 °F (18.33°C) 75 °F (23.89°C) 85 °F (29.44°C) 95 °F (35.0°C) 105 °F (40.56°C) 115 °F (46.11°C) 125 °F (51.67°C)
24AHA418A124ANS018-A30
30°F (-1.11°C)
TCG 16.60 15.60 14.70 13.80 12.90 12.00 11.10 10.10
SDT 68.50 78.00 87.50 97.00 106.50 116.00 125.40 134.70
KW 0.76 0.87 0.99 1.11 1.25 1.40 1.59 1.80
35°F (1.67°C)
TCG 18.30 17.20 16.30 15.30 14.30 13.30 12.30 11.20
SDT 69.70 79.20 88.70 98.20 107.60 117.00 126.30 135.50
KW 0.76 0.87 0.99 1.11 1.25 1.41 1.59 1.80
40°F (4.44°C)
TCG 20.00 19.00 17.90 16.90 15.80 14.70 13.60 12.40
SDT 71.10 80.50 89.90 99.40 108.70 118.00 127.20 136.30
KW 0.77 0.88 0.99 1.11 1.25 1.41 1.59 1.80
45°F (7.22°C)
TCG 22.00 20.80 19.70 18.50 17.40 16.20 14.90 13.60
SDT 72.50 81.90 91.30 100.60 109.80 119.00 128.20 137.20
KW 0.77 0.88 0.99 1.12 1.26 1.41 1.59 1.80
50°F (10.0°C)
TCG 24.00 22.80 21.60 20.40 19.10 17.80 16.40 15.00
SDT 74.00 83.40 92.60 101.90 111.00 120.10 129.20 138.20
KW 0.77 0.88 0.99 1.12 1.26 1.41 1.59 1.80
55°F (12.78°C)
TCG 26.30 25.00 23.60 22.30 20.90 19.50 18.00 16.40
SDT 75.60 84.80 94.10 103.20 112.30 121.30 130.30 139.20
KW 0.78 0.88 1.00 1.12 1.26 1.42 1.60 1.80
24AHA424A30 124ANS024-A
30°F (-1.11°C)
TCG 21.40 20.20 19.00 17.80 16.60 15.40 14.20 12.90
SDT 71.90 81.30 90.70 100.00 109.30 118.50 127.70 136.80
KW 1.01 1.15 1.30 1.46 1.64 1.85 2.09 2.36
35°F (1.67°C)
TCG 23.50 22.20 20.90 19.60 18.30 17.00 15.60 14.20
SDT 73.50 82.80 92.10 101.30 110.50 119.60 128.70 137.70
KW 1.02 1.16 1.30 1.47 1.65 1.86 2.09 2.37
40°F (4.44°C)
TCG 25.70 24.40 23.00 21.60 20.20 18.70 17.20 15.60
SDT 75.10 84.30 93.50 102.60 111.80 120.80 129.80 138.80
KW 1.02 1.16 1.31 1.47 1.66 1.86 2.10 2.38
45°F (7.22°C)
TCG 28.20 26.70 25.20 23.70 22.10 20.50 18.90 17.10
SDT 76.70 85.90 95.00 104.10 113.10 122.10 131.00 139.80
KW 1.03 1.17 1.32 1.48 1.66 1.87 2.11 2.39
50°F (10.0°C)
TCG 30.80 29.20 27.50 25.90 24.20 22.40 20.60 18.70
SDT 78.50 87.50 96.60 105.60 114.60 123.40 132.20 140.90
KW 1.04 1.18 1.32 1.49 1.67 1.88 2.12 2.39
55°F (12.78°C)
TCG 33.60 31.80 30.10 28.30 26.40 24.50 22.40 20.30
SDT 80.30 89.30 98.30 107.20 116.10 124.90 133.50 142.00
KW 1.05 1.18 1.33 1.50 1.68 1.89 2.13 2.40
24AHA430A30 124ANS030-A
30°F (-1.11°C)
TCG 27.20 25.80 24.40 22.90 21.40 19.70 17.90 16.00
SDT 69.90 79.20 88.60 98.00 107.30 116.60 125.80 134.80
KW 1.22 1.39 1.57 1.77 2.00 2.27 2.58 2.94
35°F (1.67°C)
TCG 30.10 28.50 27.00 25.40 23.70 21.90 20.00 17.90
SDT 71.20 80.60 89.90 99.20 108.50 117.70 126.80 135.80
KW 1.22 1.40 1.58 1.78 2.01 2.28 2.58 2.94
40°F (4.44°C)
TCG 33.10 31.40 29.70 28.00 26.20 24.30 22.20 20.00
SDT 72.70 82.00 91.20 100.50 109.70 118.90 127.90 136.90
KW 1.23 1.41 1.59 1.80 2.03 2.29 2.59 2.94
45°F (7.22°C)
TCG 36.50 34.50 32.70 30.80 28.80 26.80 24.50 22.10
SDT 74.30 83.50 92.70 101.90 111.00 120.10 129.10 137.90
KW 1.25 1.43 1.61 1.82 2.05 2.31 2.60 2.95
50°F (10.0°C)
TCG 40.00 37.90 35.80 33.80 31.60 29.40 27.00 24.40
SDT 76.00 85.10 94.20 103.40 112.40 121.40 130.30 139.00
KW 1.27 1.45 1.64 1.84 2.07 2.33 2.62 2.95
55°F (12.78°C)
TCG 43.80 41.40 39.20 36.90 34.60 32.10 29.50 26.70
SDT 77.90 86.90 95.90 104.90 113.90 122.80 131.50 140.20
KW 1.29 1.47 1.66 1.87 2.09 2.35 2.64 2.97
16 Specifications subject to change without notice. PDS124ANS-06
CONDENSER ONLY RATINGS (CONT.)
* AHRI listing applies only to systems shown in Combination Ratings table.
KW - Outdoor Unit Kilowatts Only.
SDT - Saturated Temperature Leaving Compressor (°F)
SST - Saturated Temperature Entering Compressor (°F/°C)
TCG - Gross Cooling Capacity (1000 Btuh)
SST °F (°C)
CONDENSER ENTERING AIR TEMPERATURES °F (°C)
55°F (12.78°C) 65°F (18.33°C) 75°F (23.89°C) 85°F (29.44°C) 95°F (35.0°C) 105°F (40.56°C) 115°F (46.11°C) 125°F (51.67°C)
124ANS036-A
30°F (-1.11°C)
TCG 31.40 29.80 28.20 26.40 24.60 22.70 20.60 18.50
SDT 68.70 78.10 87.50 96.80 106.20 115.50 124.70 134.00
KW 1.48 1.69 1.91 2.14 2.40 2.69 3.04 3.44
35°F (1.67°C)
TCG 34.70 32.90 31.10 29.20 27.20 25.10 22.80 20.50
SDT 70.00 79.30 88.60 97.90 107.20 116.40 125.60 134.80
KW 1.48 1.70 1.91 2.15 2.41 2.70 3.05 3.45
40°F (4.44°C)
TCG 38.20 36.20 34.20 32.10 29.90 27.60 25.20 22.60
SDT 71.30 80.50 89.80 99.10 108.30 117.40 126.50 135.60
KW 1.49 1.70 1.92 2.16 2.42 2.72 3.06 3.45
45°F (7.22°C)
TCG 42.00 39.80 37.60 35.30 32.90 30.30 27.70 24.80
SDT 72.80 81.90 91.10 100.30 109.40 118.50 127.50 136.40
KW 1.50 1.72 1.94 2.18 2.44 2.73 3.07 3.46
50°F (10.0°C)
TCG 46.00 43.60 41.10 38.60 36.00 33.20 30.20 27.20
SDT 74.40 83.40 92.50 101.60 110.60 119.60 128.50 137.30
KW 1.52 1.74 1.96 2.20 2.46 2.75 3.08 3.47
55°F (12.78°C)
TCG 50.20 47.60 44.90 42.10 39.20 36.20 32.90 29.60
SDT 76.10 85.00 94.00 103.00 111.90 120.80 129.50 138.20
KW 1.54 1.76 1.98 2.22 2.48 2.77 3.10 3.48
124ANS048-A
30°F (-1.11°C)
TCG 41.50 39.50 37.40 35.40 33.20 30.80 28.20 25.40
SDT 73.40 82.60 91.90 101.20 110.40 119.50 128.60 137.50
KW 2.05 2.30 2.57 2.87 3.21 3.60 4.05 4.56
35°F (1.67°C)
TCG 45.70 43.40 41.20 38.90 36.50 33.90 31.10 28.10
SDT 75.10 84.30 93.40 102.60 111.70 120.80 129.70 138.60
KW 2.08 2.33 2.60 2.90 3.24 3.63 4.08 4.60
40°F (4.44°C)
TCG 50.10 47.70 45.20 42.70 40.10 37.20 34.20 30.90
SDT 77.00 86.00 95.10 104.10 113.20 122.10 131.00 139.70
KW 2.12 2.36 2.63 2.93 3.27 3.67 4.12 4.64
45°F (7.22°C)
TCG 54.80 52.20 49.50 46.70 43.80 40.70 37.40 33.80
SDT 78.90 87.80 96.80 105.80 114.70 123.50 132.20 140.80
KW 2.15 2.39 2.66 2.96 3.31 3.71 4.16 4.69
50°F (10.0°C)
TCG 59.90 56.90 54.00 51.00 47.80 44.40 40.70 36.80
SDT 80.90 89.80 98.60 107.50 116.30 125.00 133.60 142.00
KW 2.19 2.43 2.70 3.00 3.34 3.74 4.20 4.72
55°F (12.78°C)
TCG 65.20 62.00 58.80 55.40 51.90 48.20 44.20 39.90
SDT 83.10 91.80 100.50 109.30 117.90 126.50 134.90 143.20
KW 2.24 2.47 2.73 3.03 3.38 3.78 4.24 4.76
124ANS060-A
30°F (-1.11°C)
TCG 53.00 50.30 47.70 45.10 42.40 39.40 36.00 32.40
SDT 76.00 85.10 94.30 103.50 112.70 121.70 130.60 139.40
KW 2.59 2.90 3.23 3.61 4.03 4.52 5.08 5.71
35°F (1.67°C)
TCG 58.30 55.30 52.50 49.70 46.60 43.30 39.70 35.70
SDT 78.00 87.00 96.10 105.20 114.20 123.10 131.90 140.60
KW 2.64 2.94 3.28 3.65 4.08 4.58 5.14 5.78
40°F (4.44°C)
TCG 63.90 60.70 57.60 54.50 51.10 47.50 43.60 39.30
SDT 80.00 88.90 97.90 106.90 115.80 124.70 133.30 141.90
KW 2.69 2.99 3.32 3.70 4.14 4.63 5.20 5.84
45°F (7.22 °C)
TCG 70.00 66.50 63.10 59.60 55.90 51.90 47.60 42.90
SDT 82.20 91.00 99.90 108.80 117.60 126.30 134.80 143.20
KW 2.74 3.04 3.38 3.76 4.19 4.69 5.27 5.91
50°F (10.0°C)
TCG 76.40 72.60 68.80 65.00 60.90 56.50 51.80 46.70
SDT 84.60 93.30 102.00 110.70 119.40 127.90 136.30 144.50
KW 2.80 3.10 3.43 3.81 4.25 4.76 5.33 5.97
55°F (12.78°C)
TCG 83.30 79.10 74.90 70.60 66.10 61.30 56.10 50.60
SDT 87.00 95.60 104.20 112.80 121.20 129.60 137.80 145.80
KW 2.86 3.15 3.49 3.87 4.31 4.82 5.39 6.04
PDS124ANS-06 Specifications subject to change without notice. 17
GUIDE SPECIFICATIONS
GENERAL
SYSTEM DESCRIPTION
Outdoor-mounted, air-cooled, split-system air conditioning unit
suitable for ground or rooftop installation. Unit consists of a scroll-
type hermetic compressor, an air-cooled coil, propeller-type
condenser fan, and a control box. Unit discharges supply air
horizontally as shown on contract drawings.
Unit should be used in a refrigeration circuit to match up to a
packaged fan coil or furnace.
Quality Assurance
Unit is rated in accordance with the latest edition of AHRI
Standard 210.
Unit is certified for capacity and efficiency, and listed in the
latest AHRI directory.
Unit construction complies with latest edition of ANSI/
ASHRAE and with NEC.
Unit is constructed in accordance with UL standards and
carries the UL label of approval. Unit has c-UL approval.
Unit cabinet is capable of withstanding Federal Test Method
Standard No. 141 (Method 6061) 500-hr salt spray test.
Air-cooled condenser coils are leak tested and pressure tested
Unit is constructed in a ISO9001 approved facility.
Delivery, Storage, and Handling
Unit is shipped as single package only and is stored and
handled per unit manufacturers recommendations.
Warranty (for inclusion by specifying engineer)
U.S. and Canada only.
PRODUCTS
Equipment
Factory assembled, single piece, air−cooled air conditioning
unit. Contained within the unit enclosure is all factory wiring,
piping, controls, compressor, refrigerant charge Puron
(R−410A), and special features required prior to field
start−up.
Unit Cabinet
Unit cabinet is constructed of galvanized steel and
bonderized.
Fans
Condenser fan is direct−drive propeller type, discharging air
horizontally
AIR-COOLED, SPLIT-SYSTEM AIR CONDITIONER
124ANS
1-1/2 TO 5 NOMINAL TONS
Condenser fan motors are totally enclosed, 1-phase type with
class B insulation and permanently lubricated bearings.
Shafts are corrosion resistant.
Fan blades are statically and dynamically balanced.
Condenser fan openings are equipped with coated steel wire
safety guards
Compressor
Compressor is a scroll-type, hermetically sealed.
Compressor is mounted on rubber vibration isolators.
Condenser Coil
Condenser coil is air cooled.
Coil is constructed of aluminum fins mechanically bonded to
copper tubes which are then cleaned, dehydrated, and sealed.
Refrigeration Components
Refrigeration circuit components include liquid-line front-
seating shutoff valve with sweat connections, vapor-line
front-seating shutoff valve with sweat connections, system
charge of Puron (R-410A) refrigerant, and compressor oil.
Unit is equipped with high-pressure switch and filter drier for
Puron refrigerant.
Operating Characteristics
The capacity of the unit meets or exceeds ________________
Btuh at a suction temperature of _____ °F/°C. The power
consumption at full load does not exceed _________ kW.
Combination of the unit and the evaporator or fan coil unit has
a total net cooling capacity of _____
Btuh or greater at conditions of _____ CFM entering air
temperature at the evaporator at _____ °F/°C wet bulb and
_____ F/C dry bulb, and air entering the unit at _____ F/C.
The system has a SEER of _____ Btuh/watt or greater at DOE
conditions.
Electrical Requirements
Nominal unit electrical characteristics is _____ v, single
phase, 60 hz. The unit is capable of satisfactory operation
within voltage limits of _____ v to _____ v.
Nominal unit electrical characteristics is _____ v, three phase,
60 hz. The unit is capable of satisfactory operation within
voltage limits of _____ v to _____ v.
Unit electrical power is a single point connection.
Control circuit is 24V.
Special Features
Refer to the section of this literature identifying accessories
and descriptions for specific features and available
enhancements.
Copyright 2020 Bryant Hearing and Cooling Systems D3300 Riverwood Parkway Atlanta GA, 30339 Edition Date: 05/20 Catalog No. PDS124ANS-06
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Replaces: PDS124ANS-05