Loading...
20-149 Encroachment Agreement, GTE Mobilnet of California Limited Partnership, dba Verizon Wireless, R.O.W, 10330 N Wolfe RdHeather M. Minner Kirsten Squarcia 11/12/20 T-1TITLE SHEETDRAWN BY:CHECKED BY:BMAPEIT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESSTHEY ARE ACTING UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT004/03/20100% CDREVDATEDESCRIPTIONMODUS, LLC240 STOCKTON ST., 3RD FLOORSAN FRANCISCO, CA94108APPROVED BY:LJBSF_CUPERTINO_104(NEAR) 10330 N WOLFE RDCUPERTINO, CA 95014VERIZON WIRELESS2785 MITCHELL DRIVE, SUITE 9WALNUT CREEK, CA94598105/29/20 100% CD PLAN CHECKSITE ID:SITE TYPE:POLE #:COUNTY:SF_CUPERTINO_104LIGHT POLE19617SANTA CLARASF_CUPERTINO_104(NEAR) 10330 N WOLFE RDCUPERTINO, CA 95014SITE INFORMATIONSITE ADDRESS:OWNER:APPLICANT:LATITUDE:LONGITUDE:COUNTY:ASSESSORS PARCEL NUMBER:ZONING:ELEVATION:CITY OF CUPERTINO10300 TORRE AVECUPERTINO, CA 95014VERIZON WIRELESS2785 MITCHELL DRIVE, SUITE 9WALNUT CREEK, CA 9459837.328478 NAD83-122.014167 NAD83SANTA CLARAPUBLIC RIGHT OF WAYNEAR 316-20-099CITY OF CUPERTINO174.59' AMSLVICINITY MAPPOLE PHOTONDRAWING INDEXT-1SHEET NO.TITLE SHEETT-2GENERAL NOTESA-1SITE PLAN & ENLARGED SITE PLANA-2A-4ELEVATIONSCIRCUIT DIAGRAMD-1DETAILSCODE COMPLIANCEALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENTEDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHINGIN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES.·2019 CALIFORNIA CODE·2019 CALIFORNIA BUILDING CODE (CBC), BASED ON THE 2018 IBC·2019 CALIFORNIA RESIDENTIAL CODE (CRC), BASED ON THE 2018 IRC·2019 CALIFORNIA ELECTRICAL CODE (CEC), BASED ON THE 2017 NEC·2019 CALIFORNIA MECHANICAL CODE (CMC), BASED ON THE 2018 UMC·2019 CALIFORNIA PLUMBING CODE (CPC), BASED ON THE 2018 UPC·2019 CALIFORNIA GREEN BUILDINGS STANDARDS CODE (CALGREEN)·2019 CALIFORNIA FIRE CODES WITH ALL LOCAL AMENDMENTS·ANY LOCAL BUILDING CODE AMENDMENTS TO THE ABOVE·CITY / COUNTY ORDINANCESSHEET TITLEE-1ELECTRICAL GENERAL NOTESE-2ONE-LINE DIAGRAM & GROUNDING SCHEMATIC E-3ELECTRICAL DETAILSACCESSIBILITY REQUIREMENTS FOR PERSONS WITH DISABILITIES:FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. ACCESSIBILITY ISNOT REQUIRED IN ACCORDANCE WITH CALIFORNIA ADMINISTRATIVE STATECODE PART 2, TITLE 24, CHAPTER 11B, SECTION 1103B.10330 N WOLFE RDSURVEYPROJECT TEAMPROJECT DESCRIPTIOND-2DETAILSTHE UTILITIES SHOWN HEREIN ARE FOR THE CONTRACTORS CONVENIENCEONLY. THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE PLANS. THEENGINEER/SURVEYOR ASSUMES NO RESPONSIBILITY FOR THE LOCATIONSSHOWN AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFYALL THE UTILITIES WITHIN THE LIMITS OF THE WORK. ALL DAMAGE MADE TOTHE (E) UTILITIES BY THE CONTRACTOR SHALL BE THE SOLE RESPONSIBILITYOF THE CONTRACTOR.CALL 811 BEFORE YOU DIGIT'S THE LAWMODUS PROJECT MANAGER:MODUS, LLC240 STOCKTON ST., 3RD FLOORSAN FRANCISCO, CA 94108PHONE: (415) 989.1102EMAIL: VERIZONPOLYGONTEAM@MODUSLLC.COMCONSTRUCTION/IMPLEMENTATION MANAGER:MODUS, LLC240 STOCKTON ST., 3RD FLOORSAN FRANCISCO, CA 94108PHONE: (415) 989.1102EMAIL: VERIZONPOLYGONTEAM@MODUSLLC.COMA&E PROJECT MANAGER:MODUS, LLC240 STOCKTON ST., 3RD FLOORSAN FRANCISCO, CA 94108PHONE: (415) 989.1102EMAIL: VERIZONPOLYGONTEAM@MODUSLLC.COMAPPLICANT:VERIZON WIRELESS2785 MITCHELL DRIVE, SUITE 9WALNUT CREEK, CA 94598CONTACT: CHRIS MOLLERPHONE: (925) 339.2778EMAIL: CHRIS.MOLLER@VERIZONWIRELESS.COMLAND USE PLANNER:MODUS, LLC240 STOCKTON ST., 3RD FLOORSAN FRANCISCO, CA 94108PHONE: (415) 989.1102EMAIL: VERIZONPOLYGONTEAM@MODUSLLC.COMSITE ACQUISITION:MODUS, LLC240 STOCKTON ST., 3RD FLOORSAN FRANCISCO, CA 94108PHONE: (415) 989.1102EMAIL: VERIZONPOLYGONTEAM@MODUSLLC.COM(NEAR) 10330 N WOLFE RDCUPERTINO, CA 95014SITED-3DETAILSC-1A-3ELEVATIONSVERIZON WIRELESS PROPOSES TO INSTALL A NEW WIRELESS COMMUNICATION SITE ON A LIGHT POLE IN THE PUBLIC RIGHT-OF-WAY.SCOPE:·INSTALL (1) 2' NEW CANISTER ANTENNA INSIDE NEW FRP CONCEALMENT SHROUD ON TOP OF POLE·INSTALL (2) 5G ANTENNA/RADIOS INSIDE NEW FRP CONCEALMENT SHROUD ON TOP OF POLE·INSTALL (1) RRUS 8843, (1) RRUS 4408, (1) RRUS 2205 RADIOS IN EQUIPMENT CONCEALED PEDESTAL BASE·INSTALL (2) PSU-AC08 BEHIND RADIOS IN EQUIPMENT CONCEALED PEDESTAL BASE·INSTALL NEW COAX FROM EQUIPMENT TO NEW ANTENNA WITHIN POLE·INSTALL (1) NEW DISCONNECT / SMART METER ON SIDE OF POLE·INSTALL (1) NEW AC LOAD CENTER IN EQUIPMENT CONCEALED PEDESTAL BASE·INSTALL NEW PEDESTAL BASE POLE AND FOUNDATION TO REPLACE EXISTING S/LS/LS/LS/LFIBERFIBERFIBERFIBERFIBERFIBERFIBERS/LS/LS/LS/LS/L DRAWN BY:CHECKED BY:BMAPEIT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESSTHEY ARE ACTING UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT004/03/20100% CDREVDATEDESCRIPTIONMODUS, LLC240 STOCKTON ST., 3RD FLOORSAN FRANCISCO, CA94108APPROVED BY:LJBSF_CUPERTINO_104(NEAR) 10330 N WOLFE RDCUPERTINO, CA 95014VERIZON WIRELESS2785 MITCHELL DRIVE, SUITE 9WALNUT CREEK, CA94598105/29/20 100% CD PLAN CHECK207/22/20 100% CD PLAN CHECKA-1SITE PLAN1ENLARGED SITE PLANNSITE PLAN2N2A-1ENLARGED SITE PLANN WOLFE RD A.P.N.:316-20-099(E)CONCRETE SIDEWALK 1/16"=1'-0"SCALE1/2"=1'-0"SCALE1&2A-21&2A-3(N) LOCATION OF VERIZONWIRELESS CANISTER ANTENNA IN FRPSHROUD MOUNTED ON LIGHT POLE(N) LOCATION OF VERIZON WIRELESSEQUIPMENT MOUNTED ON LIGHT POLEN WOLFE RD(E) FACE OF THE CURB(E) TREE, TYP.37'-8"± BACK OFCABINET TOPROPERTY LINE(N) LOCATION OF VERIZONWIRELESS CANISTERANTENNA AND EQUIPMENT10330N WOLFE RDCUPERTINO,CA 95014ELECTRICAL LINESTREET LIGHT LINE ES/LFIBER LINE(S)FIBERLEGENDNC1 EC1(N) STEEL MAST ARM(E) LUMINAIREN2N1EC2 NC2NC3 (N) EQUIPMENT CONCEALED PEDESTALBASE BY MANUFACTURERN WOLFE RD 37'-8"± BACK OFCABINET TO ROWLINE(E)LANDSCAPE (E)CONCRETE SIDEWALK (E)LANDSCAPE (E) FENCE (E) PROPERTY LINE PERIMETER RD(E) FACE OF THE CURB(E) FENCE (E) MEDIAN (E) PULL BOX(E)LANDSCAPE(E) FACE OF THE CURB(E) PULL BOX4'-2"±NOTE:SEE SHEET A-4 FOR CONDUCTORS ANDEQUIPMENT TO BE INSTALLED FOR POWER RUN.NOTES:1. OLD FOUNDATION BASE TO BE FILLED WITHCONTROLLED DENSITY FILL TO WITHIN 12" OFFINISH GRADE. CAP WITH PLANTING SOIL.2. LANDSCAPE AND IRRIGATION TO BERESTORED TO MATCH EXISTING FINISHELEVATIONS222UPDATED 9-4-2020 SHUTDOWNDRAWN BY:CHECKED BY:BMAPEIT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESSTHEY ARE ACTING UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT004/03/20100% CDREVDATEDESCRIPTIONMODUS, LLC240 STOCKTON ST., 3RD FLOORSAN FRANCISCO, CA94108APPROVED BY:LJBSF_CUPERTINO_104(NEAR) 10330 N WOLFE RDCUPERTINO, CA 95014VERIZON WIRELESS2785 MITCHELL DRIVE, SUITE 9WALNUT CREEK, CA94598105/29/20 100% CD PLAN CHECK207/22/20 100% CD PLAN CHECKA-2EXISTING & PROPOSEDELEVATIONS12PROPOSED ELEVATIONEXISTING ELEVATION1/2"=1'-0"SCALE1/2"=1'-0"SCALEEXISTING SURFACE0'-0" AGLEXISTING SURFACE0'-0" AGLNOTES:1. ALL NEW ANTENNAS, BRACKETS, AND OTHER EQUIPMENT WILL BE PAINTED TO MATCH LIGHT POLE.2. ALL EXISTING SIGNAGE TO BE RELOCATED SHALL BE FASTENED USING STEEL BANDING PER SHEETT-2.3. INSPECT EXISTING POLE FOR DENTS AND REPLACE POLE AS DIRECTED BY THE CITY4. POLE AND ALL APPURTENANCES TO BE PAINTED TO MATCH EXISTING(N) LIGHT POLE(E) FOUNDATION TO BE REPLACED(E) LIGHT POLE TO BE REPLACED(E) LUMINAIRE(E) ROAD SIGN(E) ROAD SIGN37'-8" BACK OF POLE TO ROW LINE38'-5" BACK OF POLE TO ROW LINET.O. (N) EQUIPMENT ENCLOSURE4'-0" AGLT.O. (E) STEEL LIGHT POLE26'-11" AGLT.O. (E) LIGHT SENSOR30'-5" AGLB.O. (E) SIGN6'-9" AGLT.O. (E) SIGN8'-3" AGL(E) LIGHT ARM SUPPORT24'-6" AGL(E) LIGHT ARM26'-3" AGLB.O. (E) SIGN6'-9" AGLT.O. (E) SIGN8'-3" AGL4D-2(N) FOUNDATION(E) LUMINAIRE(N) NOTICE SIGNAGEFACING STREETSIDE12D-1(N) MAST ARMT.O. (N) STEEL LIGHT POLE29'-11" AGLT.O. (N) LIGHT SENSOR30'-6" AGL(N) (2) 5G ANTENNASIN FRP SHROUD6D-1(N) VERIZON WIRELESSCANISTER ANTENNA4D-1(N) FRP CONCEALMENTSHROUD1D-1RAD CENTER OF (P) 5G ANTENNA31'-7" AGLT.O. (P) CONCEALMENT SHROUD35'-6" AGLRAD CENTER OF (P) CANISTER ANTENNA34'-3" AGLT.O. (N) NOTICE SIGNAGE24'-9" AGL7D-18D-15D-111D-1(N) VERIZON WIRELESS EQUIPMENT CONCEALEDWITHIN PEDESTAL BASE-(1) RRUS 8843, (1) 4408, (1) 2205-(2) PSU AC08-(1) AC LOAD CENTER-(1) TWIN DIPLEXER-(1) FIBER DEMARC BOX4E-31D-23E-3B.O. (N) DISCONNECT7'-0" AGLT.O. (N) DISCONNECT8'-9" AGL(N) SMART METER / DISCONNECTw/ SHUTDOWN SIGNAGE4D-310D-19D-13D-1PORT HOLE LOCATIONFOR DISCONNECT5D-32UPDATED 9-4-2020 Encroachment Agreement - Cuper 104.planshts Final Audit Report 2020-11-12 Created:2020-10-29 By:Julia Kinst (juliak@cupertino.org) Status:Signed Transaction ID:CBJCHBCAABAAoUQc4Ha4Bg5g7kIDzYlNrzD8wCwCzxei "Encroachment Agreement - Cuper 104.planshts" History Document created by Julia Kinst (juliak@cupertino.org) 2020-10-29 - 5:30:39 PM GMT- IP address: 64.165.34.3 Document emailed to Heather M. Minner (minner@smwlaw.com) for signature 2020-10-29 - 5:31:42 PM GMT Email viewed by Heather M. Minner (minner@smwlaw.com) 2020-11-12 - 5:44:10 PM GMT- IP address: 45.41.142.0 Document e-signed by Heather M. Minner (minner@smwlaw.com) Signature Date: 2020-11-12 - 5:44:50 PM GMT - Time Source: server- IP address: 52.39.49.65 Document emailed to Chad Mosley (chadm@cupertino.org) for signature 2020-11-12 - 5:44:52 PM GMT Email viewed by Chad Mosley (chadm@cupertino.org) 2020-11-12 - 7:07:41 PM GMT- IP address: 104.47.44.254 Document e-signed by Chad Mosley (chadm@cupertino.org) Signature Date: 2020-11-12 - 7:07:57 PM GMT - Time Source: server- IP address: 67.164.60.110 Document emailed to Kirsten Squarcia 11/12/20 (kirstens@cupertino.org) for signature 2020-11-12 - 7:08:00 PM GMT Document e-signed by Kirsten Squarcia 11/12/20 (kirstens@cupertino.org) Signature Date: 2020-11-12 - 7:34:39 PM GMT - Time Source: server- IP address: 148.64.105.190 Agreement completed. 2020-11-12 - 7:34:39 PM GMT